AXIS Q1635 Network Camera
Installation Guide
television reception, which can be determined by turning
Disposal and Recycling
the equipment off and on, the user is encouraged to try to When this product has reached the end of its useful life,
correct the interference by one or more of the following
measures:
dispose of it according to local laws and regulations. For
information about your nearest designated collection point,
contact your local authority responsible for waste disposal.
In accordance with local legislation, penalties may be
applicable for incorrect disposal of this waste.
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
•
•
•
Europe
This symbol means that the product shall not be
disposed of together with household or commercial waste.
Directive 2012/19/EU on waste electrical and electronic
equipment (WEEE) is applicable in the European Union
member states. To prevent potential harm to human health
and the environment, the product must be disposed of in
an approved and environmentally safe recycling process.
For information about your nearest designated collection
point, contact your local authority responsible for waste
disposal. Businesses should contact the product supplier for
information about how to dispose of this product correctly.
To be used in a residential area or a demanding electrical
environment, the product shall be connected using a
shielded network cable (STP) that is properly grounded.
Canada
This digital apparatus complies with CAN ICES-3 (Class B).
The product shall be connected using a shielded network
cable (STP) that is properly grounded.
Cet appareil numérique est conforme à la norme
CAN NMB-3 (classe B). Le produit doit être connecté à
l'aide d'un câble réseau blindé (STP) qui est correctement
mis à la terre.
This product complies with the requirements of
Directive 2011/65/EU on the restriction of the use of
certain hazardous substances in electrical and electronic
equipment (RoHS).
Europe
This digital equipment fulfills the requirements for RF
emission according to the Class B limit of EN 55022. The
product shall be connected using a shielded network cable
(STP) that is properly grounded.
China
This product complies with the requirements of the
legislative act Administration on the Control of Pollution
Caused by Electronic Information Products (ACPEIP).
This product fulfills the requirements for immunity
according to EN 61000-6-1 residential, commercial and
light-industrial environments.
This product fulfills the requirements for immunity
according to EN 61000-6-2 industrial environments.
Contact Information
Axis Communications AB
Emdalavägen 14
223 69 Lund
Sweden
Tel: +46 46 272 18 00
Fax: +46 46 13 61 30
This product fulfills the requirements for immunity
according to EN 55024 office and commercial environments
Australia/New Zealand
This digital equipment fulfills the requirements for RF
emission according to the Class B limit of AS/NZS CISPR 22.
The product shall be connected using a shielded network
cable (STP) that is properly grounded.
Japan
この装置は、クラスB 情
報技術装置です。この装置
は、家庭環境で使用することを目 的としています
が、この装置がラジオやテレビジョン受信機に近
接
して使用されると、 受信障害を引き起こすこと
があります。 取扱説明書に従って正しい取り扱い
をして下さい。 本製品は、シールドネットワーク
ケーブル(STP)を使用して接続してください。また
適切に接地してください。
Korea
이 기기는 가정용(B급) 전자파적합기기로서 주로
가정에서 사용하는 것을 목적으로 하며, 모든 지
역에서 사용할 수 있습니다. 적절히 접지된 STP
(shielded twisted pair) 케이블을 사용하여 제품
을 연결 하십시오.
Safety
This product complies with IEC/EN/UL 60950-1, Safety of
Information Technology Equipment. If its connecting cables
are routed outdoors, the product shall be grounded either
through a shielded network cable (STP) or other appropriate
method.
The power supply used with this product shall fulfill
the requirements for Safety Extra Low Voltage
(SELV) and Limited Power Source (LPS) according to
IEC/EN/UL 60950-1.
AXIS Q1635 Network Camera
Safety Information
Read through this Installation Guide carefully before installing the product. Keep the Installation
Guide for future reference.
Hazard Levels
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
Indicates a situation which, if not avoided, could result in damage
to property.
Other Message Levels
Important
Indicates significant information which is essential for the product
to function correctly.
Note
Indicates useful information which helps in getting the most out
of the product.
5
AXIS Q1635 Network Camera
Safety Instructions
NOTICE
• The Axis product shall be used in compliance with local laws and regulations.
• To use the Axis product outdoors, or in similar environments, it shall be installed in an
approved outdoor housing.
• Store the Axis product in a dry and ventilated environment.
• Avoid exposing the Axis product to shocks or heavy pressure.
• Do not install the product on unstable brackets, surfaces or walls.
• Use only applicable tools when installing the Axis product. Excessive force could cause
damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners.
• Use a clean cloth dampened with pure water for cleaning.
• Use only accessories that comply with technical specification of the product. These can be
provided by Axis or a third party.
• Use only spare parts provided by or recommended by Axis.
• Do not attempt to repair the product by yourself. Contact Axis support or your Axis
reseller for service matters.
Transportation
NOTICE
• When transporting the Axis product, use the original packaging or equivalent to prevent
damage to the product.
Battery
The Axis product uses a 3.0 V BR/CR2032 lithium battery as the power supply for its internal
real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years.
Low battery power affects the operation of the RTC, causing it to reset at every power-up. When
the battery needs replacing, a log message will appear in the product’s server report. For more
information about the server report, see the product´s setup pages or contact Axis support.
The battery should not be replaced unless required, but if the battery does need replacing, contact
6
AXIS Q1635 Network Camera
WARNING
• Risk of explosion if the battery is incorrectly replaced.
• Replace only with an identical battery or a battery which is recommended by Axis.
• Dispose of used batteries according to local regulations or the battery manufacturer's
instructions.
7
8
AXIS Q1635 Network Camera
Installation Guide
This Installation Guide provides instructions for installing AXIS Q1635 Network Camera on your
network. For other aspects of using the product, see the User Manual available at www.axis.com
Installation Steps
1. Make sure the package contents, tools and other materials necessary for the installation
are in order. See page 9 .
2. Study the hardware overview. See page 10.
3. Study the specifications. See page 15.
4. Install the hardware. See page 19.
5. Access the product. See page 19.
6. Set the focus. See page 19.
Package Contents
•
•
•
•
•
•
•
•
AXIS Q1635 Network Camera
2–pin connector block for power input
4–pin I/O connector block for connecting external devices
2–pin RS485/422 connector block (x2)
Camera stand
Allen key resitorx T20
Installation and Management Software CD
Printed materials
-
-
-
Installation Guide (this document)
Extra serial number label (x2)
AVHS Authentication key
Optional Accessories
For information about available accessories, including power accessories and outdoor housings
see www.axis.com
9
AXIS Q1635 Network Camera
5.
6.
7.
8.
I/O connector
Iris connector
Power connector
Power LED indicator
Network LED indicator
RS485/RS422 connector
Network connector (PoE)
Control button (1)
Function button (2)
microSD Card slot
Audio in
9.
10.
11.
12.
13.
14.
15.
16.
Audio out
Important
If the Axis product is installed in an external camera housing, leave an unobstructed cylinder-shaped
zone with Ø85 mm (3 3/8 in) around the lens to enable lens movements within the housing.
11
AXIS Q1635 Network Camera
LED Indicators
LED
Color
Indication
Net-
work
Green
Steady for connection to a 100 Mbit/s network. Flashes for network
activity.
Amber
Steady for connection to a 10 Mbit/s network. Flashes for network
activity.
Unlit
No network connection.
Status
Power
Green
Amber
Red
Steady green for normal operation.
Steady during startup and when restoring settings.
Slow flash for failed upgrade.
Green
Amber
Normal operation.
Flashes green/amber during firmware upgrade.
Note
• The Status LED can be configured to be unlit during normal operation. To configure, go
to Setup > System Options > Ports & Devices > LED. See the online help for more
information.
• The Status LED can be configured to flash while an event is active.
• The Status LED can be configured to flash for identifying the unit. Go to Setup > System
Options > Maintenance .
• The Power LED can be configured to be unlit during normal operation. To configure, go
to Setup > System Options > Ports & Devices > LED. See the online help for more
information.
• The Network LED can be disabled so that it does not flash when there is network traffic.
To configure, go to Setup > System Options > Ports & Devices > LED. See the online
help for more information.
12
AXIS Q1635 Network Camera
Status LED Behavior for Focus Assistant
Color
Indication
Green
Focus Assistant is enabled
The lens is optimally adjusted
Amber
Red
The camera has been moved, or an object has been inserted in front of the lens.
Exit and restart the Focus Assistant.
The lens is less optimally adjusted.
The camera has been moved, or an object has been inserted in front of the lens.
Exit and restart the Focus Assistant.
The lens is poorly adjusted.
Buzzer Signal for Focus Assistant
Buzzer
Lens
Fast interval
Medium interval
Slow interval
Optimally adjusted
Less optimally adjusted
Poorly adjusted
Status LED Behavior and Buzzer Signal for Levelling Assistant
Press and hold the function button (2) for more than two seconds to level the camera.
•
•
When the camera is level, both LEDs are steady green, and the beep is continuous.
When the camera is not level, the LEDs flash a combination of red, green and orange, and
the beep occurs at slow intervals.
Both LEDs briefly flash green to indicate that the levelling is getting better.
Connectors and Buttons
For specifications and operating conditions, see page 15.
Network Connector
RJ45 Ethernet connector with Power over Ethernet (PoE).
13
AXIS Q1635 Network Camera
NOTICE
Due to local regulations or the environmental and electrical conditions in which the product
is to be used, a shielded network cable (STP) may be appropriate or required. All cables
connecting the product to the network and that are routed outdoors or in demanding
electrical environments shall be intended for their specific use. Make sure that the network
devices are installed in accordance with the manufacturer’s instructions. For information
I/O Connector
Use with external devices in combination with, for example, tampering alarms, motion detection,
event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference
point and power (DC output), the I/O connector provides the interface to:
•
Digital output – For connecting external devices such as relays and LEDs. Connected
devices can be activated by the VAPIX® Application Programming Interface, output
buttons on the Live View page or by an Action Rule. The output will show as active
(shown under System Options > Ports & Devices) if the alarm device is activated.
•
Digital input – An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors,
etc. When a signal is received the state changes and the input becomes active (shown
under System Options > Ports & Devices).
Power Connector
2-pin terminal block for power input. Use a Safety Extra Low Voltage (SELV) compliant limited
power source (LPS) with either a rated output power limited to ≤100 W or a rated output current
limited to ≤5 A.
Mini DC connector. Use the supplied adapter.
Audio Connector
The Axis product has the following audio connectors:
•
•
Audio in (pink) – 3.5 mm input for a mono microphone, or a line-in mono signal.
Audio out (green) – 3.5 mm output for audio (line level) that can be connected to
a public address (PA) system or an active speaker with a built-in amplifier. A stereo
connector must be used for audio out.
RS485/RS422 Connector
Two terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such
as PTZ devices.
14
AXIS Q1635 Network Camera
SD Card Slot
A microSD card (not included) can be used for local recording with removable storage. For more
NOTICE
To prevent corruption of recordings, the SD card should be unmounted before removal. To
unmount, go to Setup > System Options > Storage > SD Card and click Unmount.
Note
For SD card recommendations see www.axis.com
Control Button
The control button is used for:
•
•
Resetting the product to factory default settings. See page 22.
Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS
Service. For more information about these services, see the User Manual.
Function Button
The function button has multiple functions:
•
Levelling assistant – This function helps to ensure the camera is level. Press the button
for about 3 seconds to start the levelling assistant and press again to stop the leveling
assistant. The status LED (see ) and buzzer signal (see page 13) assist levelling of the
camera. The camera is level when the buzzer beeps continuously.
•
Focus assistant – This function is used for enabling the Focus Assistant. To enable the
focus assistant, press and very quickly release the button. Press again to stop the focus
assistant. For more information, see page 20.
Specifications
Operating Conditions
The Axis product is intended for indoor use.
Product
Temperature
Humidity
AXIS Q1635
0 °C to 55 °C
(32 °F to 131 °F)
10-85% RH (non-condensing)
15
AXIS Q1635 Network Camera
I/O connector
4–pin terminal block for:
• 0 V DC (-)
• Auxiliary power (DC output)
• Digital Input
• Digital Output
Function
0 V DC (-)
DC output
Pin Notes
Specifications
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out. Max load = 50 mA
12 V DC
3–
4
Configurable
(Input or
Output)
Digital input – Connect to pin 1 to activate,
or leave floating (unconnected) to deactivate.
0 to max 30 V DC
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
0 to max 30 V DC, open
drain, 100 mA
16
AXIS Q1635 Network Camera
Setup example:
3.
4.
I/O configured as input
I/O configured as output
Power Connector
2-pin terminal block for
power input. Use a Safety
Extra Low Voltage (SELV)
compliant limited power
source (LPS) with either a
rated output power limited
to ≤100 W or a rated output
current limited to ≤5 A.
DC power input
17
AXIS Q1635 Network Camera
Audio Connector
3.5 mm audio
connectors (stereo)
1 Tip
2 Ring
3 Sleeve
Ground
Ground
Audio Input
Microphone/Line in
Line out (mono)
Audio Output
RS485/422 Connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be configured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function
Pin
Notes
1
RS485B alt
RS485/422 RX(B)
RX pair for all modes (combined RX/TX for 2-wire RS485)
2
RS485A alt
RS485/422 RX(A)
3
4
TX pair for RS422 and 4-wire RS485
RS485/RS422 TX(B)
RS485/RS422 TX(A)
Important
The recommended maximum cable length is 30 m (98.4 ft).
SD Card Slot
Supports microSD cards with up to 64 GB of storage. For best recording performance, use
a microSDHC UHS-I or microSDXC UHS-I card. In temperatures below – 25° C use industrial
grade SD card.
18
AXIS Q1635 Network Camera
Install the Hardware
NOTICE
Due to local regulations or the environmental and electrical conditions in which the
product is to be used, a shielded network cable (STP) may be appropriate or required. Any
network cables that are routed outdoors or in demanding electrical environments shall be
shielded (STP) and intended for their specific use.
1. Optionally connect external input/output devices, such as alarm devices. See on page 15
for information on the terminal connector pins.
2. Optionally connect an active speaker and/or external microphone.
3. Connect the camera to the network using a shielded network cable.
4. Connect power, using one of the methods listed below:
-
PoE (Power over Ethernet). PoE is automatically detected when the network
cable is connected.
-
Connect an external power adapter to the power connector block. See
5. Check that the indicator LEDs indicate the correct conditions. See the table on page
12 for more details. Note that the Status LED can be configured to be unlit during
normal operation.
6. Optionally insert a microSD card (not included) into the SD card slot.
NOTICE
To prevent corruption of recordings, the SD card should be unmounted before it is ejected.
To unmount, go to Setup > System Options > Storage > SD Card and click Unmount.
Access the Product
Use the tools provided on the Installation and Management Software CD to assign an IP address,
set the password and access the video stream. This information is also available from the support
pages on www.axis.com/techsup/
Adjust Focus
To adjust the zoom and focus follow these instructions:
Note
•
Set focus as precisely as possible with the focus ring or Focus Assistant before starting
automatic fine tuning. Using the focus ring normally gives the best result.
• The iris should always be opened to its maximum while focusing. This gives the smallest
depth of field and thus the best conditions for correct focusing.
19
AXIS Q1635 Network Camera
1. Open the product’s home page and go to Setup > Basic Setup > Focus.
2. Under the Basic tab, click Open iris. If the button is inactive the iris is already open.
3. If focus has been set before, click Reset to reset the back focus.
on page 10) on the lens by turning them counter-clockwise. Move the zoom puller and
the focus ring to set zoom and focus and check the quality of the image in the image
window. If the camera is mounted so that you cannot look at the image and move
the zoom puller and the focus ring at the same time, use the Focus Assistant instead.
5. Re-tighten the zoom puller and the lock screw for the focus ring.
6. On the Focus page, click Fine-tune focus automatically and wait until automatic fine
tuning is completed.
7. Click Enable iris. If the button is inactive the iris is already enabled.
8. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Focus Assistant
Note
• The view in front of the camera should not be changed during focus adjustment (steps
5 and 6). If the camera is moved, or if a finger or other object is placed in front of the
lens, steps 3 - 7 will have to be repeated.
• If movements in front of the camera cannot be avoided, the Focus Assistant should not
be used.
• If the camera is mounted so that the Function button cannot be accessed, you can still
use the Focus Assistant. Follow the instructions below but mount the camera after step
4, pressing the Function button instead and skip step 7.
1. Mount or place the camera so that it cannot be moved.
2. Loosen the zoom puller by turning it counter-clockwise. Move the puller to set the
zoom level. Re-tighten the zoom puller.
3. Set the camera to its extreme distant-focus position by loosening the lock screw for the
focus ring and turning the focus ring fully counter-clockwise.
4. Press and quickly release the Function button. When the Status LED flashes green, the
Focus Assistant is enabled.
If the Status LED flashes either red or amber before you are able to adjust the lens, skip
to step 7 to exit the Focus Assistant and repeat steps 3 - 7. See the notes above. See
5. Gently turn the focus ring clockwise until it stops.
20
AXIS Q1635 Network Camera
6. Turn the focus ring slowly counter-clockwise until the status indicator flashes green
or amber (not red).
7. To exit the Focus Assistant, press the Function button again. The Focus Assistant is
switched off automatically after 15 minutes.
8. Retighten the lock screw for the focus ring.
9. Open the Live View page in the web browser and check the quality of the image.
10. On the Focus page, click Fine-tune focus automatically and wait until automatic fine
tuning is completed.
11. Click Enable iris. If the button is inactive the iris is already enabled.
12. If needed, make further adjustments under the Advanced tab. See the online help for
more information.
Replace the Lens
It is possible to use optional lenses for the Axis product.
To replace the lens:
1. Disconnect the iris cable.
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
To change the iris configuration:
1. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
To change the iris configuration for P-iris lenses not listed in the drop-down list:
2. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
3. In Iris configuration: Click Edit.
4. Go to the Upload tab.
5. Click Browse and select the configuration file.
6. Click Upload. The installed iris lens should now be included in the Iris Selection
drop-down list.
7. Select the installed iris lens from the drop-down list and click OK.
21
AXIS Q1635 Network Camera
Note
• If you select a DC iris configuration file for a P-iris lens, an error message will appear
below the iris configuration type in the Camera Settings page. For custom DC Iris lenses,
select Generic DC Iris option.
• There is no need to restart the product after changing the lens. However, the product must
be restarted if you are interchanging between a P-iris, DC-Iris or fixed/manual iris lens. In
order to set the focus and position the lens, the product must be connected to the network.
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available on the CD supplied with the
product and from the support pages on www.axis.com/techsup
To reset the product to the factory default settings:
1. Disconnect power from the product.
page 10.
3. Keep the control button pressed for about 15–30 seconds until the status LED indicator
flashes amber.
4. Release the control button. The process is complete when the status LED indicator turns
green. The product has been reset to the factory default settings. If no DHCP server is
available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the
password, and access the video stream.
6. Refocus the product.
It is also possible to reset parameters to factory default via the web interface. Go to Setup
> System Options > Maintenance.
Further Information
The User Manual is available at www.axis.com
product. To see the currently installed firmware version, go to Setup > About.
22
AXIS Q1635 Network Camera
guides.
Warranty Information
For information about Axis’ product warranty and thereto related information, see
23
Installation Guide
AXIS Q1635 Network Camera
© Axis Communications AB, 2014
Ver. M1.2
Date: December 2014
Part No. 61117
|